US study finds adding flame retardants to foam insulation materials in buildings does not improve fire prevention, but is harmful to environment, human health; researchers call for change in building codes

Allison Oesterle

Allison Oesterle

Zug, Switzerland , November 26, 2012 (press release) – Researchers in the United States are calling for a change to the US building codes, following a study showing that the mandatory flame retardants routinely added to foam insulation are not only harmful to human health and the environment, but also make no difference to the prevention of fire in buildings where a fire-safe thermal barrier already exists. Such a change would bring the US building codes in line with regulations in Sweden and Norway.

The research team, which is drawn from US-based centres of excellence including the University of California and the Lawrence Berkeley National Laboratory, conducted a thorough review of fire safety literature since the mid-1970s and conclude that the addition of halogenated organic compounds to plastic insulation materials such as polystyrene, polyisocyanurate and polyurethane is costly, ineffective and environmentally damaging. Their conclusions are published in the latest issue of the journal Building Research and Information.

Led by internationally renowned fire expert Dr Vytenis Babrauskas of Fire Science & Technology Inc., the research team investigated the impact of the “Steiner Tunnel test”, which is used to test the propagation of fire over the surface of all sorts of building materials in the early stages of fire (before flashover point is reached). Their paper suggests that changing the US building codes to exempt foam plastic insulation materials from the test would avoid the use of thousands of tonnes of flame retardants that are known or suspected to be persistent organic pollutants. They conclude:

“Such a change would … decrease the cost of foam plastic insulation and encourage the use of insulation materials for increasing building energy efficiency and mitigating climate change. The potential for health and ecological harm from the use of flame retardant chemicals would be reduced and the fire safety of buildings would be maintained.”

Their article begins with a review of the development of the US building codes in relation to fire safety, and foam insulation in particular, and explains that foam plastics used for insulation have required a thermal barrier (usually 12.7 mm (1/2 inch) thick gypsum wallboard) since 1976. In addition, chemicals such as hexabromocyclododecane (HBCD) and Tris (1-chloro-2-propyl) phosphate (TCPP) are routinely added in order to meet the requirements of the Steiner Tunnel test. The building codes have never stipulated that chemicals be added to foam plastic insulation, however doing so is the most common way to meet the Steiner test. These additives are semi-volatile organic compounds (SVOCs) which do not bind to the insulation material and are known to be released into the environment throughout the life cycle of insulation. The chemicals can persist and accumulate, and have been implicated in thyroid hormone disruption and nervous system development problems and are potentially carcinogenic.

The experts suggest that exempting foam plastic insulation materials from the Steiner Tunnel test would mean there was no longer a need to add these flame retardants.

As well as presenting a detailed analysis of the problems associated with the Steiner Tunnel test, the article reviews the:

• Adequacy of the thermal barrier

• Fire propagation into a cavity constructed in violation of codes

• Behaviour of exposed foam insulation installed in violation of codes.

The article also discusses alternative courses of action, including the possible development of a more accurate test, the use of different flame retardant chemicals and a range of options for mitigating the impact of the flame retardants currently used.

Finally, the article says that such an action would not be without precedent. Flame retardants were once routinely added to children’s pyjamas, but their use was discontinued after a range of adverse environmental and health impacts were identified. Dr Babrauskas and his team conclude that, in the light of their evidence, an equivalent volte-face should be implemented in the US building codes as soon as possible. They also recommend a root and branch review of the process of designing fire standards and building codes, in particular to ensure that fire scientists, building code officials and other regulators consider the efficacy, life cycle, health and ecological impacts of building materials.

The full paper will be downloadable for free for a limited time from the journal website: www.tandfonline.com/doi/full/10.1080/09613218.2012.744533

Notes for Editors

  • Flame retardants in building insulation: a case for re-evaluating building codes by Vytenis Babrauskas, Donald Lucas, David Eisenberg, Veena Singla, Michel Dedeo and Arlene Blum appears in Building Research and Information, 2012, 40(6), pp 738-755.
  • Building Research & Information is an international peer-reviewed journal. www.tandfonline.com/bri
  • Not all insulation used in buildings is foam insulation. The study only focuses on foam insulation and not other types.

About Taylor & Francis Group

Taylor & Francis Group partners with researchers, scholarly societies, universities and libraries worldwide to bring knowledge to life. As one of the world’s leading publishers of scholarly journals, books, ebooks and reference works our content spans all areas of Humanities, Social Sciences, Behavioural Sciences, Science, and Technology and Medicine.

From our network of offices in Oxford, New York, Philadelphia, Boca Raton, Boston, Melbourne, Singapore, Beijing, Tokyo, Stockholm, New Delhi and Johannesburg, Taylor & Francis staff provide local expertise and support to our editors, societies and authors and tailored, efficient customer service to our library colleagues.

* All content is copyrighted by Industry Intelligence, or the original respective author or source. You may not recirculate, redistrubte or publish the analysis and presentation included in the service without Industry Intelligence's prior written consent. Please review our terms of use.

Share:

About Us

We deliver market news & information relevant to your business.

We monitor all your market drivers.

We aggregate, curate, filter and map your specific needs.

We deliver the right information to the right person at the right time.

Our Contacts

1990 S Bundy Dr. Suite #380,
Los Angeles, CA 90025

+1 (310) 553 0008

About Cookies On This Site

We collect data, including through use of cookies and similar technology ("cookies") that enchance the online experience. By clicking "I agree", you agree to our cookies, agree to bound by our Terms of Use, and acknowledge our Privacy Policy. For more information on our data practices and how to exercise your privacy rights, please see our Privacy Policy.